Light Monitoring

              Environmental Monitor
              - 765 Series
                                                                            SD-9300
              The large 8-line display allows the user to          Environmental Meter
              select more advanced functions. Data logging
              functions enable over 10,000 readings, of all        •   Datalogger with date/ time stamp
              four parameters, to be automatically taken at           stores measurements on SD
              selectable intervals (every 10 seconds to 1             memory card without the need for
              hour). The saved data can be transferred to             software
              a computer by a wireless infrared link (IRDA         •   7-in-1 environmental meter
              compatible). Most modern computers have                 measures relative humidity (RH), air
              an infrared interface built in. For those that          temperature, ambient temperature,
              do not, adaptors are available. The software            air velocity light and contact tem-
              is provided, to save the logged data in a CSV           perature measurements
              format. Maximum and minimum values, and
              their time measurement, are displayed for each       •   Measures temperature in °C or F°, light levels
              parameter. A kit is available, for user calibration     are measured in foot-candles or lux
              of the RH sensor, using saturated salt solutions.    •   Temperature Range: Type K: (-100 to 1300° C)
              Software compatible with Windows 7 and Vista,           Type J: (100 to 1200° C)
              XP. Wt. 165g. Dimensions: 5-7/8” x 2-9/16” x 1”      •   Humidity Range: 5 – 95% RH
              (includes probe).
                                    Unit measures Humidity (RH), Temperature,   •   Light Ranges: 0 – 20,000 Lux (0 to 1,860 Ft-cd)
              Specifications:       Ultra Violet (UV) and Visible Light (LUX)
                 Power Supply:                                     •   Optional PC software features live tracking via USB connection
                                                                              ®
                     • 2 x alkaline AA type batteries (not included)    (Windows  XP, and 7)
                 Ranges:                                           Cat. #   Description                          Price
                     • Visible Wavelength: 400 to 700nM            27-145  SD-9300 Environmental Monitor ................................. $479.00
                     • Visible Power: 0.1 to 200,000 Lux           27-146  Data Acquisition Software ............................................. 134.00
                     • UV Wavelength: 300 to 400nM
                                            2
                     • UV Power: 2 to 50,000 µW/M
                     • UV Proportion: 0 to 10,000 µW/Lumen         Light Meter
                     • RH Range: 0 to 100%
                 Display Resolution:                               – Designed for one hand operation
                     • Lux: 0.1 up to 100 then 1.                  Fits easily into a tool belt or pocket. Auto-ranging.
                     • Foot-candles: 0.1 up to 100 then 1          User selectable lux/foot-candles. Min/max and data
                     • UV: 0.1 up to 100 then 1                    hold function. Auto shut off and zero adjustment
                     • Proportion of UV: 1 µW/Lumen                button. Over range and low battery indication.
                     • Temperature: 0.1ºC or ºF                    Battery included.
                     • RH: 0.1%
                 Accuracy:                                         Specifications:
                     • Light and UV: 5% ±1 displayed digit                • Range: 0 to 20,000 lx; 0 to 2,000 Fc
                     • Temperature: ±0.5ºC (±0.9ºF)                       • Resolution: 1,10 lx; 0.1, 1 Fc
                     • RH: ±2.5%, 0-90% otherwise ±5%                     • Accuracy: ±0.5%
                 Logging:                                                 • Sampling Rate: 1 time/second
                     • Intervals: 10 sec(30 hrs), 1 min (7.5 days),       • Power Supply: Single 9V battery
                       10 mins(75 days), 1 hour(454 days)                 • Weight: 5.7 oz.
                     • Capacity: 10,900 readings all 4 parameters
                                                                   Cat. #   Description                          Price
              Cat. #   Description                          Price  82-475  Light Meter  ................................................................  $165.00
              684-764   Environmental Monitor  ........................................ $2635.00  82-401  Soft Carrying Case  ........................................................  23.85
              684-764C  684-764 with Data Logger  ..................................... 3185.00
              684-7647  RH Calibration Kit  ..................................................... 595.00  Light Meter
                                                                   – Accurately display light
                                                                   levels in terms of Foot-candle or
              Environment Meter
                                                                   Lux over a wide measuring range
              4-in-1 Multifunction
                                                                   User selectable lux/Foot-candles. min/max
              4-in-1 multifunction meter–humidity meter,           and data hold function. Auto shut off. Over
              light meter, thermometer and anemometer              range and low battery indication. Carrying
              in one compact unit. Light: 0 to 20,000 lux/ 0       case and battery included.
              to 2,000 Fc, auto ranging. User selectable lux/
              foot-candles. Anemometer: 0.4 to 30.0 m/s.           Specifications:
              Velocity Units: m/s, km/h, MPH, Knots, ft./                 • Range: 0 to 50,000 lx; 0 to
              min. Type K Thermometer: -100 to 1300°C.                        5,000 Fc
              °C/°F switchable. Humidity: 10 to 95%RH.                    • Resolution: 0.1 lx; 0.1 Fc
              Data hold, record (max/min). Designed for                   • Accuracy: ±0.5%
              one-hand operation. Includes battery.                       • Sampling Rate: 1.5 times/second
              Cat. #   Description                          Price         • Power Supply: Single 12V battery
                                                                          • Weight: 5.7 oz.
              82-400  Environment Meter  .................................................... $300.00
              82-401  Carrying Case  ................................................................. 23.85  82-477 .......................................................................................  $159.00